ANT

BC-ANT-SERIAL

1. Overview

BC-ANT-SERIAL is a module that is equipped with nRF24AP2-8CH, the second generation of ANT chip developed by Nordic Semiconductor. To communicates with a microcontroler (IC), it uses single-end and asynchronous serial communication (1.9V ~ 3.3V RS-232C).

DSCF7967r.JPG
※ ¥100-yen coin is placed for the reference.

2. Specification

3. Host Interface

To communicate with a microcontroler, BC-ANT-SERIAL supports single-end and asynchronous serial communication. This ANT module does not support the synchronous mode.

Assignment of pin-headers and pads are shown in the tables below. They are printed in silkscreen on the PCB.

DSCF7962r2.JPG DSCF7963r2.JPG

The lines of RST, SUP, and SLP are used for tightly managing the activity of ANT chip and increasing energy efficiency of this ANT module.
The lines of BR1, BR2, and BR3 are used for setting the speed of asynchronous serial communication.

[Caution]
In the picture, (a) is the connector, which is specifically used for attaching to the characteristic test antenna. Users are prohibited using this connector. Please do not attach any external antenna to this connector.
In the picture, (b) is the chip antenna. To maintain the characteristics of antenna, do not place any parts nor metric materials around this chip antenna.

About Control Pads

The Size of RST, SUP, SLP, BR1, BR2, and BR3 pads is identical to the size of the chip resistor 1608 pad. To wire to these pads, solder lines to these pads. The function of each line is explained below.

How to Use

(1) How to connect with the serial communication (TXD, RXD, and RTS)
Pin-headers are attached at J1. Please look at Host Interface section fro the pin assignment.
picture3.jpg

From ANT module, RTS is output for controlling hardware flow. This is considered as no-protocol serial communication with hardware flow management. As the microcontroller monitors RTS, it will not stop sending commands if the ANT module is in BUSY. If it does not use hard flow, you can replace hardware flow with another program. As confirming RTS signal is at L, then the commands are send via GPIO port. The datesheet of ANT chip specifies that the delay time between sending a command and sending the signal is at least 50μsec. Actually, to measure the duration, an RTS is sometimes required more than 50μsec to transfer L. To send a command correctly, please check an RTS signal line is at L level. BC-ANT-SERIAL does not have CTS input. In the case of using hardware flow, the microconroller has to receive the reply from the ANT module.

(2) How to Connect Control Lines (Reset, Sleep, and Suspend)
picture4.jpg

To use the lines of RST (reset), SLP (sleep), and SUP (suspend), ANT chip can be managed more efficiently. These lines make it possible that lets ANT chip suspend when there are no communications and/or that forcefully reset ANT chip if it is needed. To utilize the control lines, the ANT module is completely reset, and the energy consumption of the module is possibly reduced.

Caution and E.T.C.

About ANT communication, please look at http://www.thisisant.com
The specification document of ANT protocol is available at This is ANT, The Wireless Sensor Network Solution. Go to DEVELOPER -> DOWNLOADS under RESOURCES. Then select DOCUMENTS tab.
BC-ANT-SERIAL is equipped with nRF24AP2-8CH. 8 channels of ANT connections are available at this module.